[Skip Navigation]  

Ei Professional Smoke Alarms and Smoke Detectors

Residential Fire Safety UK Ireland

Find Product:

by type:

or model number:


If the model is not available, please contact us directly for advice.

Product Archive

Wiring Diagrams
Use & Care Manuals
Product Briefs

Battery Powered Smoke and Heat Alarms

Ei3105TYCH - Optical Smoke Alarm with Hush, Lithium Cells and Interconnect

Ei3105TYCH

Optical Smoke Alarm with Hush, Lithium Cells and Interconnect

Download Product Brief

Applications

Lithium 10 year batteries to provide long lasting life

High sensitivity – responds to all standard fires

Interconnect version (Ei 3105TYCH) – interconnect up to 12 other alarms with silencer capability

Senses smoke using the light scatter principle – quick response to visible smouldering smoke

Battery powered – 9 volt (supplied)

Built in sounder to give a minimum sound output of 85dB(A) at 3m

Warning beeps when batteries have expired and unit needs replacing

Easily installed – no wiring

Test Button simulates smoke – use to check performance at least monthly

Hush Button – silences nuisance alarms

5 year guarantee (limited)

Main Features

Lithium 10 year batteries to provide long lasting life

High sensitivity – responds to all standard fires

Interconnect version (Ei 3105TYCH) – interconnect up to 12 other alarms with silencer capability

Senses smoke using the light scatter principle – quick response to visible smouldering smoke

Battery powered – 9 volt (supplied)

Built in sounder to give a minimum sound output of 85dB(A) at 3m

Warning beeps when batteries have expired and unit needs replacing

Easily installed – no wiring

Test Button simulates smoke – use to check performance at least monthly

Hush Button – silences nuisance alarms

5 year guarantee (limited)

Installation

For full Installation and Siting Instructions please refer to the Use and Care Manual

This Alarm is battery operated and needs no wiring

Pull cover open at Tab. Remove cover from base by separating at rear snap-in hinges by rotating cover backwards

Place the base on ceiling or wall exactly where you want to mount the unit. With a pencil, mark the location of the screw holes

Taking care to avoid any electrical wiring in the ceiling or wall, drill a hole through the centres of the marked locations. Push the plastic screw anchors provided into the drilled holes. Screw in firmly

Slide back the switch in the direction indicated to connect the built-in Lithium Battery permanently

Trouble Shooting

Nuisance/False Alarms occur:

If, when the alarm goes off, there is no sign of smoke, heat or noise to indicate that there is a fire, you should get your family into a safe place, before you start investigating

Check the house carefully in case there is a small fire smouldering somewhere

Check whether there is some source of smoke or fumes, for example cooking fumes being drawn past Smoke Alarm by extractor

If there are frequent nuisance/false alarms it may be necessary to re-locate the device away from the source of the fumes

Fanning vigorously with a newspaper or similar will help silence alarm

This Smoke Alarm is designed for more difficult areas, as you can silence the alarm for about 10 minutes. This gives time for smoke or fumes to clear