[Skip Navigation]  

Ei Professional Smoke Alarms and Smoke Detectors

Residential Fire Safety UK Ireland

Find Product:

by type:

or model number:


If the model is not available, please contact us directly for advice.

Product Archive

Wiring Diagrams
Use & Care Manuals
Product Briefs

RF Optical Smoke Alarm

Ei3105 - RF Optical Smoke Alarm

Ei3105

RF Optical Smoke Alarm

Download Product Brief

Applications

The new Ei 3100 series of RF Smoke Alarms using 9Volt Alkaline batteries is designed to meet entry level installation requirements and provide wireless interconnected fire detection in domestic applications.

The unique and trusted Ei Smoke Alarm technology is now combined with current Rf developments to provide better fire detection.

Main Features

Radio transmitter and receiver in each alarm

RF range 150 metres(minimun) in free space

Uniquely coded to work with one system only

Advanced suppression and calibration technology increases reliability

Large volume, high performance optical chamber

Fitted with insect resistant screen to reduce nuisance alarms

Hush button for false alarm control

Auto self-test feature continually monitors the sensor every 40 seconds for additional safety

9Volt Alkaline Battery

Wireless interconnect with up to 12 other Ei Electronics RF smoke alarms

5 year guarantee

Installation

For full Installation and Siting Instructions please refer to the Use and Care Manual

Pull cover open at tab. Remove cover from base by separating at rear
snap-in hinges by rotating cover backwards

Place the base on the ceiling/wall exactly where you want to mount the unit. With a pencil, mark the location of the two screw holes

It may be necessary to rotate/resite units to maximise the radio link signals. Consequently we advise to use only one screw initially. Taking care to avoid any electrical wiring in the ceiling, drill one hole through the centre of one of the marked locations. Push the plastic screw anchors provided into the drilled hole. Screw in firmly. The second screw may then be used to securely fix the alarm in place after the radio link interconnection is verified

Connect the battery to the battery snap

Press the test button on each alarm to ensure that the smoke alarm works

Check the radio link interconnection by holding the test button down until the amber light has come on continuously – this indicates that the alarm is now transmitting radio link signals. You should now be able to hear the other alarm(s) in the distance. If you do not hear the other alarm(s) then you may need to rotate/resite the alarm

The units, as received, will transmit and receive the default RF signal. However, to avoid other neighbouring systems interfering with your alarms, we recommend that you “house code” your alarms

Trouble Shooting

Alarm sounds for no apparent reason:

House code your alarms. If the alarms are in the default factory settings, neighbouring units may cause them to alarm

Check for fumes, steam etc. from the kitchen or bathroom. Paint and other fumes can cause nuisance alarms

Check for any sign of contamination such as cobwebs or dust. Clean the alarm as described in use and care manual

On Ei3105RF units press the test/hush button on the unit causing the alarm (this can be identified as the alarm with the red light flashing rapidly) – this will silence the smoke alarm for 10 minutes and also silence all other smoke alarms in the system

The Alarm Fails to Sound When The Test Button is Pressed:

Check the age of the unit – see the “replace by” label on base of unit

Check the battery snaps are firmly connected

The Alarms Sound but the Wireless Interconnection does not work:

There are certain limitations on radio frequency signals and so, some alarms may not sound when the test button of a smoke alarm is pressed. Then;

Ensure you have held the test button down until the amber light has come on continuously (this could take up to 5 seconds)

House code all smoke alarms as described in the use and care manual (section 6)

Rotate and/or resite the units – the signal strength may not be sufficient due to the distance and/or the number of walls/ceilings between the units

Back to Top

 
 