The 160 Series of Easi-fit mains powered smoke and heat alarms has been designed to offer peace of mind to the specifier and end user by using proven trusted Ei technology in a new slim profile alarm that is now even easier to install. Offering the very highest standards of safety, performance and reliability you’d expect from Europe’s leading manufacturer of mains powered fire detection products, the Easi-fit 160 Series includes high performance tamper-proof 10 year life Rechargeable Lithium Cells. The combination of the most advanced detection technology with the highest perfromance back-up power system available means that the 160 Series offers the best possible all-round protection.
More responsive to slow smouldering fires
Advanced suppression and calibration technology
Large volume high performance optical chamber with proven extended life capability. Fitted with insect resistant screen
Hush button for false alarm control
Separate mains and warning LEDs
Auto self-test feature continually monitors the sensor every 40 seconds for additional safety
10 year+ Rechargeable Lithium Cell back-up designed to outlast the alarm
Precision charging circuit ensures peak cell performance
Low power cell warning in the event of a mains or cell failure
Interconnects with other Ei Professional mains powered smoke and heat alarms
Easi-fit mounting plate – simpler and quicker to install
Connects to manual call point MCP 400
Connects to remote Test and Hush switch Ei152
5 year guarantee includes rechargeable cells
For full Installation and Siting Instructions please refer to the Installation Instructions and User Instructions
Ideally install in the centre of ceiling at least 300mm(1ft) from light fittings. Keep ionisation alarms away from kitchens to prevent nuisance alarms. Interconnect all alarms
Remove unit from mounting plate by releasing catch
Connect the house wiring to the mounting plate, noting the live, neutral, IC and earth connections
Ensure house live mains is correctly connected to L terminals on all interconnected alarms – otherwise units will be damaged
Do not fit actual alarm until all building work is completed to avoid contamination. After checking operation, cover smoke alarm with dust cover until required for use
Don’t megger the alarm. Disconnect the alarm before applying high voltage to house wiring
Frequent nuisance Alarms occur:
Close kitchen/bathroom door when in use
Ensure that the alarm is sited at least 6m away from sources of fumes
Contamination from insects, paint or paint fumes may have occured. Clean the alarm
Alarm sounds for no apparent reason:
Identify the alarm source. On interconnected units, the red light on the cover will flash rapidly only on the unit which is the source of the alarm
Check for fumes, steam etc. from the kitchen or bathroom. Paint and other fumes can cause nuisance alarms
Press the test/hush button to silence the Smoke/Heat Alarm for 10 minutes
If the alarm does not stop, switch off mains and remove unit.(only remove alarm with red light flashing, the others are probably satisfactory)
Low battery & other beeps:
Check the green mains light is on. If not, check fuse, circuit breakers and wiring connections. If the green light is off, the lithium cells will deplete after some months without mains and will need to be recharged. If the above fails to turn on the green light, a fault may exist. Switch off mains and remove the unit
If the green mains light is on and replacing battery, recharging the lithium cells or cleaning has not stopped beeps, a fault may exist. Disconnect the mains first and replace the unit
Interconnected Alarms do not all sound:
Hold test button for 10 seconds after first alarm has sounded to ensure signal is transmitted to all units
Switch off mains and check that live, neutral and interconnect cables have been correctly connected and that the connections are tight