Mains (AC Powered) Smoke and Heat Alarms

Ei164 - Heat with Hush

Ei164

Heat with Hush

Download Product Brief

Applications

The 160 Series of Easi-fit mains powered smoke and heat alarms has been designed to offer peace of mind to the specifier and end user by using proven trusted Ei technology in a new slim profile alarm that is now even easier to install. Offering the very highest standards of safety, performance and reliability you’d expect from Europe’s leading manufacturer of mains powered fire detection products, the Easi-fit 160 Series includes high performance tamper-proof 10 year life Rechargeable Lithium Cells. The combination of the most advanced detection technology with the highest perfromance back-up power system available means that the 160 Series offers the best possible all-round protection.

Main Features

Ideal for protecting kitchens and garages

Advanced suppression and calibration technology

Fixed temperature fast response thermistor type sensor, range 54°C – 62°C

Hush button for false alarm control

Separate mains and warning LEDs

10 year+ Rechargeable Lithium Cell back-up designed to outlast the alarm

Precision charging circuit ensures peak cell performance

Low power cell warning in the event of a mains or cell failure

Interconnects with other Ei Professional mains powered smoke and heat alarms

Easi-fit mounting plate – simpler and quicker to install

5 year guarantee includes rechargeable cells

Installation

For full Installation and Siting Instructions please refer to the Installation Instructions and User Instructions

Ideally install in the centre of ceiling at least 300mm(1ft) from
light fittings. Interconnect all alarms

Remove unit from mounting plate by releasing catch

Connect the house wiring to the mounting plate, noting the live, neutral, IC and earth connections

Ensure house live mains is correctly connected to L terminals on all interconnected alarms – otherwise units will be damaged

Do not fit actual alarm until all building work is completed to avoid contamination. After checking operation, cover smoke alarm with dust cover until required for use

Don’t megger the alarm. Disconnect the alarm before applying high voltage to house wiring

Trouble Shooting

Frequent nuisance Alarms occur:

Close kitchen/bathroom door when in use

Ensure that the alarm is sited at least 6m away from sources of fumes

Contamination from insects, paint or paint fumes may have occured. Clean the alarm

If the problem persists, resiting of the unit should be considered. Alternatively, replace the unit with an Optical unit(EI145/146/166), assuming that the problem is with an Ionisation type alarm(EI140/141/161).

Alarm sounds for no apparent reason:

Identify the alarm source. On interconnected units, the red light on the cover will flash rapidly only on the unit which is the source of the alarm

Check for fumes, steam etc. from the kitchen or bathroom. Paint and other fumes can cause nuisance alarms

Press the test/hush button to silence the Smoke/Heat Alarm for 10 minutes

If the alarm does not stop, switch off mains and remove unit.(only remove alarm with red light flashing, the others are probably satisfactory)

Low battery & other beeps:

(On EI141/144/146 only)

If the battery is correctly connected and the unit has beeped for over 20 minutes the battery is probably depleted. Obtain a new battery, disconnect the mains, then remove the alarm and replace the depleted battery

(On EI161/164/166 only)

Check the green mains power light is on. If not, check fuse, circuit breakers and wiring connections. If the green light is off,the lithium cells will deplete after some months without mains and will need to be recharged. If the above fails to turn on the green light, a fault may exist. Switch off mains and remove the unit

(All Alarms)

If the green mains light is on and replacing battery, recharging the lithium cells or cleaning has not stopped beeps, a fault may exist. Disconnect the mains first and replace the unit

The Ionisation units(EI141/140/161) give two beeps 10 minutes after the test/hush button is pressed

If the Optical units (EI146/145/166) beeps without the red light flashing at the same time, the chamber is defective. Clean the chamber

Interconnected Alarms do not all sound:

Hold test button for 10 seconds after first alarm has sounded to ensure signal is transmitted to all units

Switch off mains and check that live, neutral and interconnect cables have been correctly connected and that the connections are tight