Advanced detection technology coupled with superior 10 year+ rechargeable Lithium Cell back-up has made the 150 Series a market leader and the first choice for specifiers nationwide. The 150 Series popularity and reliability over the last 10 years is proven by the fact that several million units have now been specified and installed by Councils and Housing Associations and are currently protecting thousands of households throughout the UK.
More responsive to slow smouldering fires
Features the large, advanced Ei optical chamber with proven extended life capability. Fitted with insect resistant screen
Hush button for false alarm control
Separate mains and warning LEDs
Low power cell warning in the event of mains or cell failure
Interconnects with other EI Professional mains powered smoke & heat alarms
Precision charging circuit ensures peak cell performance
Proven 10 year+ rechargeable lithium cell back-up
Connects to manual call point MCP 400
Connects to remote Test and Hush switch Ei152
5 year guarantee includes rechargeable cells
For full Installation and Siting Instructions please refer to the Installation Instructions and User Instructions
Ideally install in the centre of ceiling at least 300mm(12”) from light fittings. Interconnect all alarms
Ensure live mains is correctly connected to brown Smoke Alarm wire on the interconnected alarms – otherwise units will be damaged
Do not fit actual alarm until all building work is completed to avoid contamination. After checking operation, cover smoke alarm with dust cover until required for use
Don’t megger the alarm. Disconnect the alarm before applying high voltage to house wiring
Frequent nuisance Alarms occur:
Close kitchen/bathroom door when in use
Ensure that the alarm is sited at least 6m away from sources of fumes
Contamination from insects, paint or paint fumes may have occured. Clean the alarm
Alarm sounds for no apparent reason:
Identify the alarm source. On all interconnected units, the red light under the test button or on the cover will flash rapidly only on the unit which is the source of the alarm
Check for fumes, steam etc. from the kitchen or bathroom. Paint and other fumes can cause nuisance alarms
Press the hush button to silence the Smoke Alarm
If the alarm does not stop, switch off mains and remove unit.(only remove alarm with red light flashing, the others are probably satisfactory)
Alarms beeps continuously:
Cells may be flat due to mains failure. Check the green mains light is on. If not, check fuse, circuit breakers and wiring connections
If the above fails to turn on the green light, a fault may exist. Switch off mains and remove the unit, or press the hush button
If the green mains light is on and the action in (bullet point 1) above has not silenced the beeping, a fault may exist. Remove the unit
Interconnected Alarms do not all sound:
Hold test button for 10 seconds after first alarm has sounded to ensure signal is transmitted to all units
Switch off mains and check that live, neutral and interconnect cables have been correctly connected and that connections are tight