Battery Powered Smoke and Heat Alarms

Ei100L - Ionisation Smoke Alarm with Escape Light

Ei100L

Ionisation Smoke Alarm with Escape Light

Download Product Brief

Applications

Particularly useful for locations such as stairs and exits routes where the high intensity light beam will illuminate the escape route.

Main Features

High intensity light beam powered by alkaline battery

High sensitivity – responds to all standard fires

Dual ionisation chamber – quick response to fast flaming fires

Battery powered – 9 volt (supplied)

Built in sounder to give a minimum sound output of 85dB(A) at 3m

Bleeps every 40 seconds when battery needs replacing

Easily installed – no wiring

Test Button simulates smoke – use to check performance at least monthly

5 year guarantee (limited)

Installation

For full Installation and Siting Instructions please refer to the Use and Care Manual

This Alarm is battery operated and needs no wiring

Pull cover open at Tab. Remove cover from base by separating at rear snap-in hinges

Place the base on ceiling or wall exactly where you want to mount the unit. With a pencil, mark the location of the screw holes

Taking care to avoid any electrical wiring in the ceiling or wall, drill a hole through the centres of the marked locations. Push the plastic screw anchors provided into the drilled holes. Screw in firmly

With a pencil, write the date of battery installation on the inside of the cover to remind you when to replace the battery. Lift battery from battery holder, and snap battery connectors to battery. They fit together only one way. Gently push battery into battery holder. To close the cover match up snap-in hinges and gently press together until base and cover snap together

All models are fitted with a warning flag which pops up when the battery is removed. This prevents the cover from closing when there is no battery in the unit. When the battery is being installed or changed, this flag must be held down while gently pushing the battery into the battery holder

Trouble Shooting

Nuisance/False Alarms occur:

If, when the alarm goes off, there is no sign of smoke, heat or noise to indicate that there is a fire, you should get your family into a safe place, before you start investigating

Check the house carefully in case there is a small fire smouldering somewhere

Check whether there is some source of smoke or fumes, for example cooking fumes being drawn past Smoke Alarm by extractor

If there are frequent nuisance/false alarms it may be necessary to re-locate the device away from the source of the fumes

The Silencer Smoke Alarm Ei100S is designed for more difficult areas, as you can silence the alarm for 8 minutes. This gives time for smoke or fumes to clear